FM Transmitter Measurement Report
Created: 2025-05-08 01-32-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 69 dBuV YLEX
Pilot RDS Phase Difference
7.6 kHz 2.4 kHz 55 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19059 0,4460
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,1 dBr 3,17 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 1:32, 8.05.2025
RT
"YleX Iltapäivä: Päivän parhaat "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,4460 Acquired: 2025/05/08 1.31.51 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,1 dBr MIN: -1,1 dBr AVE: 3,17 dBr % above 12,2 dBr: 0,0 Last value: 1,6 dBr (2025/05/08 1.31.50) 01.18 01.20 01.22 01.24 01.26 01.28 01.30 -2 0 2 4 6 Pm [dBr]